We offer a 1:1 custom replacement for the DAF65-12C01, replicating the original encoder's 0-10V absolute output and mechanical specifications. This solution allows for seamless drop-in installation without the need for modifications, providing a practical and reliable alternative for clients facing procurement challenges or requiring immediate replacements. With a production lead time of 15 working days, this replacement ensures quick availability for industrial applications.
Engineered for stable voltage-loop feedback over long cable distances and in electrically noisy environments, this replacement encoder ensures accurate absolute position readings. It is ideal for automation systems, process control machinery, and material handling equipment that demand precise and reliable feedback.
Reference Images


Electrical data
| Parameter | Value |
| Valid for all versions | Unless otherwise stated |
| Sensor system: | GaAIAs diode, photo-transistor array, precision comparator |
| Setting cycles EEPROM: | ≥10^6 |
| Multifunctional inputs (MFP): | Depending on adjusting mode (signal input E6) |
| Memory circuit (latch): | Through MFP |
| Disc coding: | Gray code |
| Signal sense: | CW or CCW (signal input E6) |
| Supply voltage range V_s: | +20 to +26 VDC, 15±0.5VDC(optional) |
| Supply current I_s: | 80 mA typ. / 120 mA max. (when output current = 0) |
| Linearity: | 0.025% typ. / 0.05% max. (+2 LSB), 12 Bit monotory warranted |
| Temperature drift: | 0.0015% / K typ. |
| Current output | |
| Accuracy | |
| at starting point 0 mA: | 0 mA ±5 μA typ. / ±15 μA max. |
| at end point 4 mA: | 4 mA ±5 μA typ. / ±15 μA max. |
| Load resistance: | 0 to 500Ω at V_s = 20 to 26 VDC, 0 to 1000Ω at V_s = 22 to 26 VDC |
| Voltage output | |
| Accuracy | |
| at starting point 0 V: | 0 V ±2.5 mV typ. / ±7.5 mV max. |
| at end point 10 V: | 10 V ±2.5 mV typ. / ±7.5 mV max. |
| Output current: | 5 mA max. When load resistance > 2 kΩ (short circuit proof) |