For discontinued or difficult-to-source CR105-4096G24C12 parallel absolute encoders, we provide a precision 1:1 technical replacement engineered for seamless system continuity. The solution accurately replicates original housing dimensions, mounting configuration, shaft specifications, and parallel signal output format. It supports direct installation into existing equipment without PLC reprogramming or mechanical modification, helping reduce retrofit complexity and lower overall replacement costs.
With a standard production lead time of approximately 15 working days, this solution effectively supports urgent maintenance demands and small-batch non-standard customization. Each encoder undergoes strict signal calibration and environmental reliability testing to ensure stable and accurate performance under continuous industrial workloads. It is widely applied in automation systems, heavy-duty machinery, and positioning equipment requiring dependable parallel absolute feedback and long-term operational stability.


Technical data
| Parameter | Value |
|---|---|
| Resolution | 2 to 4096 positions / 360° |
| Measuring range | 2 to 4096 turns |
| Total number of positions | |
| Measurement position deviation | |
| Output frequency* | 30 kHz max. up to 10 Bit / 360°; 10 kHz max. from 11 Bit |
| Disc coding | Gray code |
| Output code, parallel | Gray or Natural Binary |
| Code sense, serial | CW or CCW (Signal input E2) |
| Logic polarity | Positive |
| Memory circuit | Store or not store, signal input E1 |
| Enable circuit (for bus operation) | Active or inactive, (signal input E1) |
| Sensor system | GaAlAs diodes, photo-transistor array |
| Parallel output circuits | A = Open collector Darlington; B = Open collector, TTL compatible; C = Open emitter Darlington; D = Push-pull, Totem-pole |
| Serial output SSI | Differential data output to RS 422 |
| Clock input SSI | Differential (opto-coupler) for data driver to RS 422 |
| Supply voltage range | +11 V to +26 VDC |
| Supply current | Parallel: 90 mA typ. / 120 mA max.; Serial GSI: 130mA typ. / 160mA max. |
| Operating speed | 3000 rpm max. (continuous); 4000 rpm max. (short period) |
| Angular acceleration | 10° rad/s² max. |
| Inertial mass of rotor | ≤ 5 Ncm (8 Ncm - CR 66) |
| Wind-up torque | ≤ 1 Nm (4 Ncm - CR 66) |
| Permissible axial and radial shaft load | 250 N max. |
| Bearing life expectancy | 10⁹ revolutions |
| Operating temperature range | -20°C to +60°C |
| Storage temperature range | -25°C to +70°C |
| Permissible rel. humidity | 85% without condensation |
| Resistance to shock | 200 m/s², 11 ms (DIN IEC 68) |
| Resistance to vibration | 5 Hz..1000 Hz; 100 m/s² (DIN IEC 68) |