The C‑FG40KK‑1024G‑90G‑NG‑S incremental encoder is a high‑precision feedback device designed for industrial motion control, automation systems, and machinery where accurate incremental pulse output is essential. As specific legacy encoder variants become increasingly difficult to source through regular supply channels, a tailored replacement solution has been developed to replicate the original’s mechanical form, electrical interfaces, and signal characteristics on a one‑to‑one basis.
This engineered alternative encoder matches the original unit’s installation dimensions, shaft configuration, and output parameters, enabling seamless integration into existing systems without requiring changes to mounting hardware, cabling, or control logic. It is suitable for demanding industrial applications such as conveyor drives, indexing systems, and automated production lines where consistent position feedback is crucial. The custom replacement supports predictable lead times and technical guidance for integration, helping maintenance teams minimize downtime and extend equipment operational life.
Custom configurations, including extended pulse rates and tailored electrical interfaces, are also available to meet specific equipment requirements, ensuring stable performance and long‑term availability for critical installations.


Technical data
| Parameter | Value |
|---|---|
| Pulse rates | |
| Standard pulse rates | 500, 600, 1000, 1024, 1200, 2000, 2048, 2400, 2500 |
| Special pulse rates | 4000, 4096, 4800, 5000, 8192, 10000, 12000, 16000, 16384, 20000, 25000, 40000, 50000 (further pulse rates according to customer specification) |
| Connection data | |
| Supply voltage | 12 V … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| No load-current | approx. 50 mA at 24 V |
| Outputs | Current limited, short-circuit proof push-pull line driver with integrated impedance adaptation for 30 to 140 Ω lines |
| Pulse height (HTL) | approx. as supply voltage, output saturation voltage < 0.4 V at Iₗ 30 mA |
| Output current | max. 150 mA at 24 V (observe derating) |
| Internal resistance | 75 Ω bei 24 V |
| Slew rate | 200 V/μs with C_L 100 pF |
| Duty cycle | 1:1 ± 3 % for standard pulse rates 1:1 ± 5 % for special pulse rates up to 25000 pulses |
| Square wave displacement 0°, 90° | 90° ± 3 % for standard pulse rates 90° ± 5 % for special pulse rates up to 25000 pulses |
| Max. frequency | 200 kHz, Higher max. frequency on request |
| Special output voltage 5V (TTL) | |
| Pulse height | 5V, RS422-compatible (TIA/EIA-Standard) |
| Supply voltage | 12 … 30 V DC (optional: 5 V DC) For UL and CSA Class 2 supplied |
| Alternative Connection Data (from image(1)_1.png) | |
| Supply voltage | 5 V … 30 V DC For UL and CSA Class 2 supplied |
| No load-current | Approx. 120 mA at 5 V, approx. 50 mA at 24 V |
| Output signals | 2 sinusoidal signals A and B each with inverted signals Reference pulse with inverted signal Signal amplitude 1 V pp / R_L = 120 Ω Error signal and inverted signal Signal amplitude 5V |
| Resolution | 1024 signal periods |
| Duty cycle | 1 ± 0.1 |
| Phase shift A, B | 90° ± 1° |