We offer a 1:1 custom replacement for the DAF66-12C01, replicating the original 0-10V absolute output and mechanical specifications. This solution guarantees seamless integration into existing systems without the need for modifications. With a standard production lead time of just 15 working days, it provides a fast and effective option for clients facing procurement challenges or in need of immediate replacements.
Engineered for accurate voltage-loop feedback over long cable distances and in electrically noisy environments, this encoder ensures precise absolute position readings. It is ideal for industrial automation, process control, and material handling systems that demand reliable and consistent performance.
Reference Images


Electrical data
| Parameter | Value |
| Valid for all versions | Unless otherwise stated |
| Sensor system: | GaAIAs diode, photo-transistor array, precision comparator |
| Setting cycles EEPROM: | ≥10^6 |
| Multifunctional inputs (MFP): | Depending on adjusting mode (signal input E6) |
| Memory circuit (latch): | Through MFP |
| Disc coding: | Gray code |
| Signal sense: | CW or CCW (signal input E6) |
| Supply voltage range V_s: | +20 to +26 VDC, 15±0.5VDC(optional) |
| Supply current I_s: | 80 mA typ. / 120 mA max. (when output current = 0) |
| Linearity: | 0.025% typ. / 0.05% max. (+2 LSB), 12 Bit monotory warranted |
| Temperature drift: | 0.0015% / K typ. |
| Current output | |
| Accuracy | |
| at starting point 0 mA: | 0 mA ±5 μA typ. / ±15 μA max. |
| at end point 4 mA: | 4 mA ±5 μA typ. / ±15 μA max. |
| Load resistance: | 0 to 500Ω at V_s = 20 to 26 VDC, 0 to 1000Ω at V_s = 22 to 26 VDC |
| Voltage output | |
| Accuracy | |
| at starting point 0 V: | 0 V ±2.5 mV typ. / ±7.5 mV max. |
| at end point 10 V: | 10 V ±2.5 mV typ. / ±7.5 mV max. |
| Output current: | 5 mA max. When load resistance > 2 kΩ (short circuit proof) |