For discontinued or long lead-time PAM90H15-BF6XXR-4096/8192 Profibus hollow shaft encoders, we provide a precision 1:1 technical replacement engineered for seamless system continuity. The solution accurately matches original mounting dimensions, hollow shaft specifications, and Profibus-DP communication parameters. It allows direct installation without PLC reconfiguration or structural modification, helping reduce retrofit risk and overall replacement costs while ensuring stable multiturn absolute feedback.
With a controlled production cycle of 10–15 working days, this solution supports urgent maintenance needs and small-batch non-standard customization. The encoder offers programmable resolution up to 8192 steps and multiturn capability up to 4096 revolutions, meeting demanding motion control requirements. Each unit undergoes strict communication validation and load testing to guarantee reliable performance under vibration, axial and radial stress, and fluctuating industrial temperatures.


Technical data
Mechanical parameters
| Parameter | Details |
|---|---|
| Shaft diameter | Φ12H7/Φ16H7/Φ20H7/Φ24H7/Φ28H7Φ(6H7)/Φ8/Φ11H7/Φ12p6×30 mm |
| Protection class | IP65 |
| Speed | Max 6000 rpm continuous; Max 3000 rpm |
| Max load capacity of the shaft | axial: 40 Nradial: 80 N |
| Shock resistance | 2500 m/s², 6 ms |
| Vibration resistance | 100 m/s², 10…2000 Hz |
| Bearing life | 10⁷ revolutions |
| Moment of inertia | -72 × 10⁻⁶ kg·m²hollow shaft < 0.2 Nm |
| Starting torque | shaft acc. to EN 605 Nm≤ 0.05 Nm |
| Body material | AL - alloy |
| Housing material | AL - alloy |
| Operating temperature | -20…+80 °C |
| Storage temperature | -25…+85 °C |
| Relative humidity/condensation | 90%, Condensation not permitted |
| Weight | ≤ 900 g |
Electrical parameters
| Parameter | Details |
|---|---|
| Supply voltage (U₍ₚₚₗₙ₎) | 10…30 VDC |
| Power consumption | Max 0.20 A |
| Linearity | ± 1/2 LSB(± 1 LSB 13/14 bit 2) |
| Interface | RS 485 |
| Protocols | Profibus - DP, encoder profile class 2 |
| Baud rate | Max. 12 Mbit/s |
| Address | programmable via DIP switches |