We provide ATM90-AUM12x12 encoder replacement solutions, the use of non-standard form for the production of alternative products, the application parameters of all 1:1. Perfect replacement of the prototype encoder, to solve the procurement and other challenges. The picture is the real photo of the replacement solution.
Detailed technical data
Safety-related parameters
Parameter
Value
MTTF (mean time to dangerous failure)
150 years (EN ISO 13849-1)
Performance
Parameter
Value
Number of steps per revolution (max. resolution)
4,096 (12 bit)
Number of revolutions
4.096 (12 bit)
Max. resolution (number of steps per revolution x number of revolutions)
12 bit x 12 bit (4,096 x 4,096)
Resolution
Ex-works: 4,096 steps x 4,096 revolutions, Gray-Code, Set = 0 factory-programmed. Other configurations on request.
Measuring step
0.043°
Error limits G
±0.25°
Repeatability standard deviation
0.1°
Interfaces
Parameter
Value
Communication interface
SSI
Initialization time
1,050 ms
Parameterising data
Number of steps per revolution, Number of revolutions, Code type, Electronic adjustment