Custom engineering support is available for HMG11 S13 H2048 20H7 KLK for maintenance, retrofit, replacement, and upgrade requirements. Typical production lead time: 15 working days. This model can be supported through a compatible solution where singleturn SSI absolute feedback and 2048-pulse HTL incremental output need to remain aligned with the original field installation.
Technical Overview of the HMG11 S13 H2048 20H7 KLK Encoder
This version is a mixed-output configuration that combines 13-bit singleturn SSI absolute data with an additional HTL incremental output of 2048 pulses. The 20 mm blind hollow shaft and radial terminal box indicate a mechanically robust platform intended for industrial feedback installations where both absolute position reference and pulse-based auxiliary feedback are required.
Industrial Integration Considerations
Compared with the 1024-pulse variant, this configuration places more emphasis on controller pulse-handling capability. During retrofit, both the SSI channel and the 2048-pulse HTL output should be checked against the original control hardware so that timing, counting behavior, and voltage-level compatibility remain stable. The application should also be reviewed for any limits related to high pulse frequency on the receiving input.
Field Installation and Wiring Notes
The KLK terminal-box layout supports practical field replacement, but mixed-output wiring requires disciplined segregation of SSI and incremental lines. Clock/Data continuity, HTL pulse signal routing, shield grounding, and cable separation from power conductors should be maintained carefully. On the mechanical side, the 20 mm shaft fit and anti-rotation fixing should be checked before startup, especially in high-vibration machinery. Cable entry sealing should also be reviewed for long-term field reliability.
Custom Compatible Encoder Solution
The custom compatible solution for this version is generally built around SSI singleturn continuity, HTL 2048-pulse incremental output matching, 20 mm shaft adaptation, KLK terminal-box wiring preservation, and original installation geometry. Project-specific signal expectations should be confirmed during engineering review.
Custom Solution Photos


Lead Time and Custom Development
Typical production lead time: 15 working days. Custom development support is available for projects that need to preserve both SSI absolute behavior and higher-pulse HTL incremental output continuity.
Typical Technical Parameters
| Parameter | Specification |
|---|---|
| Interface | SSI |
| Singleturn Resolution | 13 bit / 8192 steps |
| Multiturn Resolution | Not included in this coded version |
| Additional Output | HTL incremental, 2048 pulses |
| Output Code | Gray |
| Clock Frequency | 100...800 kHz |
| Shaft Type | Blind hollow shaft, 20H7 |
| Connection | Terminal box, radial (KLK) |
| Voltage Supply | 9...30 VDC |
| Protection | IP67 |