The HMG11 S25 Z0 16H7 KLK encoder can be supported through a custom compatible solution for maintenance, retrofit, replacement, and upgrade applications. Typical production lead time: 15 working days. For installations that rely on SSI absolute feedback through a radial terminal box, the solution can be engineered to preserve signal continuity, shaft fit, and field wiring access with reduced change to the existing layout.
Technical Overview of the HMG11 S25 Z0 16H7 KLK Encoder
This version uses SSI communication with 13-bit singleturn plus 12-bit multiturn absolute data. The 16H7 blind hollow shaft provides direct mechanical fit on a 16 mm shaft, while the KLK radial terminal box makes this variant especially relevant in applications where service access and field termination space are important. SSI versions on this platform use Gray code and defined clock/data timing characteristics.
Industrial Integration Considerations
In SSI retrofit work, the main integration issue is usually timing compatibility rather than network profile settings. Controller input requirements, SSI clock generation, data word length, and direction interpretation should be checked carefully. Because this is a 13-bit plus 12-bit multiturn version, the receiving controller must interpret both position within one turn and accumulated turn information in the expected format.
Field Installation and Wiring Notes
The KLK radial terminal box version is well suited for field replacement where direct access to terminals is preferred. Clock, Data, supply, and ground continuity should be checked carefully, and cable routing should be kept separate from inverter or motor power lines to support signal stability. For SSI systems, clock frequency and data timing should remain within the documented range, and shield grounding should be handled consistently at the panel side according to the existing EMC practice. The 16 mm hollow shaft and torque arm fixing point should also be checked during installation.
Custom Compatible Encoder Solution
A custom compatible solution for this version is usually based on SSI signal structure, 13-bit plus 12-bit multiturn data length, 16 mm shaft fit, KLK terminal-box routing, and field wiring continuity. Where the existing control system uses a defined Gray-code interpretation or specific timing window, that should be matched during engineering review.
Custom Solution Photos


Lead Time and Custom Development
Typical production lead time: 15 working days. Custom development is available for projects requiring preservation of SSI timing behavior, terminal access style, and original installation geometry.
Typical Technical Parameters
| Parameter | Specification |
|---|---|
| Interface | SSI |
| Singleturn Resolution | 13 bit / 8192 steps |
| Multiturn Resolution | 12 bit |
| Output Code | Gray |
| Clock Frequency | 100...800 kHz |
| Additional Output | Without additional output |
| Shaft Type | Blind hollow shaft, 16H7 |
| Connection | Terminal box, radial (KLK) |
| Voltage Supply | 9...30 VDC |
| Protection | IP67 |